MINILAB • 25–150 GPD

MiniLab: purified water for your compact laboratory.

Supply your glassware rinse, autoclave feed and analytical preparation with a compact water system. PPT configures MiniLab treatment and monitoring around your required ASTM grade, daily use and available installation space.

MiniLab water purification platform with treatment equipment and storage
Product overview

Purified water for your small lab and shared utilities.

MiniLab supplies water for your glassware rinse, autoclaves, analytical preparation and shared laboratory utilities where space and demand are limited. PPT configures RO treatment, polishing and final filtration around your equipment’s water-quality requirements, with a compact layout that leaves access for routine service.

  • Compact applications

    Rinse, autoclave and preparation water.

  • Selectable water quality

    ASTM grades for your equipment.

  • Controls choices

    MiniLab or MiniLab Plus.

Configuration & capabilities

Compare MiniLab controls and monitoring.

Choose the water quality your equipment needs, then select how your team will operate and monitor the system. MiniLab and MiniLab Plus share the configurable purification design; alarms, logging and facility integration distinguish the controls packages.

Swipe across the table to review the configuration details.

MiniLab configuration comparison
MiniLabCore controlsMiniLab PlusExpanded monitoring & integration
Water-quality optionsASTM Type II/III/IV, as configuredASTM Type II/III/IV, as configured
Operator interfaceBasic HMIEnhanced HMI / PLC
Alarms & monitoringEssential system alarmsExpanded alarms, trends and history
Facility integrationLocal, standalone operationOptional network / BMS / SCADA integration
Published technical specifications
Published system specifications
ParameterPublished / configurable value
Production rate25–150 GPDConfigurable low-flow lab range.
Product waterASTM Type II/III/IV
Primary treatmentRO with optional DI polishing
Microbial controlUV and final filtration
MonitoringConductivity/resistivity, temperatureOptional TOC as needed.
DistributionLoop support up to 600 ftAs designed.
Side view of MiniLab treatment equipment and connections
Engineering & operation

RO, polishing and filtration for your required water grade.

Reverse osmosis provides primary treatment. PPT selects DI polishing, UV and final filtration around your equipment specifications, required ASTM grade and point-of-use requirements.

  1. Reverse osmosis

    Primary treatment stage.

  2. Configured polishing

    DI and UV selected for the method.

  3. Final filtration

    Matched to the point of use.

Treatment sequence is conceptual. Final stages and connections follow the selected configuration.

Monitoring, controls and construction

Measurement

Review conductivity/resistivity, temperature and any optional TOC monitoring your application needs. Your selected controls package determines how readings and alarms are presented.

Distribution and construction

The specification lists loop support up to 600 feet as designed. Materials, finishes and any sanitary requirements are selected to the URS and site standards.

Supply your lab equipment without oversizing your system.

Size your water supply around your equipment and daily use.

Request a Spec Review

Bring drawings, specifications or defined equipment requirements.

  • Glassware rinse and autoclave feed

    Plan rinse and make-up water around your equipment specifications, operating cycles and required recovery time.

  • Analytical preparation and small-batch work

    Review water for your spectrophotometry, electrochemistry, preparation and buffer work against each method’s quality requirements.

  • University and biotech laboratories

    Supply your shared teaching benches, research spaces and pilot-support equipment where footprint and modest daily consumption favor a compact platform.

  • Production, storage and simultaneous draw

    Share your equipment list, required quality, daily volume and peak use. Review storage and distribution separately from the water your RO system produces.

  • Installation space and controls

    Identify your available footprint, utility connections and filter-change access. Tell PPT whether you need local operation, alarm history or integration with your building controls.

Keep filters, polishing and service access in your operating plan.

Access and documentation

Include your filter and DI access, maintenance instructions and turnover documents in the configuration review. Your lab needs room to replace consumables after installation.

Operating support

Plan consumable replacement and preventive maintenance for your installed treatment stages. PPT can review your readings, alarms and equipment details when troubleshooting changes in performance.

Water services & support

Review MiniLab for your lab equipment and available space.

Send your required water quality, equipment list, daily volume and installation dimensions. PPT can review treatment, storage, controls and maintenance access for your compact lab.

Privacy settings

Choose whether to allow optional analytics. You can change your choice at any time using Privacy Settings in the footer.

Necessary functionality

Supports your privacy choices and features you request, such as inquiry forms and Osmo. Rejecting analytics does not disable these features.

Always available

Read our Privacy Policy and Cookie Policy.